Tests provided by IAPMO India Lab Facility

  • E.coli
  • Coliform
  • Legionella
  • Feacal streptococci and Staphylococcus aureus
  • Sulphite reducing anaerobes
  • Pseudomonas aeuroginosa
  • Aerobic microbial count
  • Yeast and mould
  • Salmonella and shigella
  • Vibrio cholerae and Vibrio parahaemolyticus
  • Virucidal Efficacy Estimation with MS2 and phi X 174 coliphages in water purifiers
  • Virucidal Efficacy Estimation with Saccharomyces cerevisiae reduction in water purifiers
  • Cyst enumeration test
  • Turbidity, Colors, Total Dissolved Solids, pH
  • Barium, Copper, Iron, Manganese, Zinc, Silver, Aluminium, Selenium, Calcium, Megnesium,
    Sodium, Potassium, Antimony, Cadmium, Arsenic, Lead, Chromium, Nickel
  • Borate, Nitrate, Nitrite, Fluoride, Chloride, Sulphate and Cyanide
  • Residual Chlorine, Total hardness and Alkalinity
  • Phenolic compounds as C6H5OH, Polychlorinated biphenyls as PCB,
    Polynuclear aromatic hydrocarbons, Pesticides and Mineral Oil
  • Anionic Surface active agents as MBAS
  • VOCs and SVOCs
  • Microbiological reduction
  • Chemical reduction

NSF / ANSI - 42

NSF / ANSI - 53

NSF / ANSI - 55

NSF/ANSI 58

Materials in contact with Drinking Water

Materials in contact with Drinking Water
Volatile organic compounds
Semi Volatile organic compounds
Regulated and other metallic elements
Nitrosamines

Materials in contact with Drinking Water Materials in contact with Drinking water
Materials evaluation Materials evaluation Materials evaluation

Material evaluation

Structural performance Design & Construction Structural performance

Structural performance

  • Structural integrity
  • Working pressure
  • Performance indication of
  • chemical reduction capacity
  • Elements
  • Flow control
  • Waste connections
  • Product water dispensing
  • outlets
  • Hazards
  • Systems used in bottled
  • water plants
  • Operating temperature
  • Structural integrity

Structural integrity

Minimum performance requirements

Chemical, mechanical and structural performance

Minimum performance requirements

Minimum performance requirements

  • Elements
  • Waste connections
  • Product water dispensingoutlets
  • Hazards
  • Operating temperature
  • Electrical safety and operation
  • Rated service flow
  • Minimum service flow
  • Active ingredients and additives
  • Aesthetic effects claims
  • Chemical reduction claims
  • Mechanical filtrationreduction claims
  • Structural integrity
  • Filter media
  • Rated pressure drop
  • Minimum service flow
  • Elements
  • Waste connections
  • Product water dispensing outlets
  • Hazards
  • Operating temperature
  • Electrical safety and operation
  • Rated service flow
  • Minimum service flow

Flow control

Mandatory testing for elective claims

Mandatory testing for elective claims

 

Reject water connections

  • General requirements
  • Bacteriological performance
  • Chemical reduction testing requirement
  • Chloramines reduction
  • requirement
  • Chlorine reduction
  • requirement
  • Hydrogen Sulphide and
  • phenol reduction
  • Iron and Manganese
  • reduction requirement
  • pH adjustment requirements
  • Zinc reduction requirements
 
  • General requirements
  • Microbiological performance

Storage tank capacity

Mechanical reduction testing

   

Product water dispensing outlets

  • Nominal particulate
  • reduction (85%) classes
  • Scale control testing
   

Drinking water fountain outlets

Installation, operation, and maintenance instructions

Installation and information

Installation and information

Performance indication

  • Data pale
  • Replacement
  • Components
  • Performance data sheet
  • Data pale
  • Replacement
  • Components
  • Performance data sheet
  • Data pale
  • Replacement
  • Components
  • Performance data sheet

TDS reduction, recovery rating, and efficiency rating,

     

Elective performance claims

     

Chemical reduction claims

     

Mechanical filtration claims

     

Instructions and Information

  • IS14724:1991 (RA2009) Ultraviolet-Based Water Purifiers — Specification
  • IS16240:2015 Reverse Osmosis-Based Point-of-Use Water Treatment systems — Specification
  • WQIA Protocol: IP 100 Guide Standard and Protocol for Microbiological Evaluation of Drinking Water Treatment Devices
  • IAPMO WPSC-01:2019 Evaluation of point of use water purification systems – specification
  • NSF/ANSI 42 Drinking Water Treatment Units — Aesthetic Effects
  • NSF/ANSI 53 Drinking Water Treatment Units — Health Effects
  • NSF/ANSI 55 Ultraviolet Microbiological Water Treatment Systems
  • NSF/ANSI 58 Reverse Osmosis Drinking Water Treatment Systems
  • WQA S — 200 Voluntary Industry Standard for Residential & Commercial Water Filters
  • WQA S — 300 Voluntary Industry Standard for Point-Of-Use Low Pressure Reverse Osmosis Drinking Water Systems
  • NSF P231 Microbiological Water Purifiers
  • WHO Evaluating Household Water Treatment Options: Health-Based Targets and Microbiological Performance Specifications: 2011
  • US EPA Guide Standard and Protocol for Testing Microbiological Water Purifiers
  • Chlorine reduction
  • Chloramine reduction
  • Turbidity reduction
  • TDS reduction
  • Lead reduction at pH 6.5 and 8.5
  • Arsenic III and V reduction tests at pH 6.5 and 8.5
  • Reduction tests of various other metals, namely mercury, chromium, cadmium, copper, selenium, etc.
  • Klebsiella, E. coli, MS2 phage reduction tests
  • Cyst reduction (microspheres) tests
  • Global migration of plastics
  • Metal leaching tests
  • Quality characteristics of detergents and sanitizers
  • Autopsy of RO membranes
  • ISO221961 Plastics- Measurement of antibacterial activity on plastic surfaces
  • JISZ2801 Antimicrobial products – Test for antimicrobial activity and efficacy
  • NSF/ANSI 372 Drinking water Systems components – Lead content
  • WEP- I ( Water efficiency Products) testing for water faucets, valves, mixers, sanitary water closets and cisterns
  • Faucet Life cycle testing as per ASME standard. Customised protocols are considered
Scroll to top